使用活细胞细胞外ATP实时测量
找到答案,如何执行实时测量Promega´s细胞外ATP装备与活细胞CLARIOstar ACU +。
找到答案,如何执行实时测量Promega´s细胞外ATP装备与活细胞CLARIOstar ACU +。
找出TRUPATH平台结合PHERAstar FSX可以用来研究GPCR交互,从而可以提前opoid止痛药更安全的发展。
有很多方法来监控ROS生成。但很少有简单、快速、敏感的表演Promega ROS-GloTM化验BMG LABTECH微型板块的读者。
你想执行交互研究,而不必执行蛋白质纯化?读到这里,如何占有CETSA PROTAC-target交互可以用来研究一个内生的测试系统。
困难比较结果由于温度变化?阅读这里的冷却功能如何PHERAstar FSX AAS使稳定温度和绕过了这些问题。
寻找一种快速、简单,敏感的方式监视你的葡萄糖代谢细胞培养?在这里阅读如何VANTAstar提供最大方便使用发光检测。
Malebari是;E艾哈迈德,H; Ihmaid, SK;奥马尔,我;穆罕默德,丫;Althagfan,党卫军;Aljuhani, N; El-Sayed, AA; Halawa,啊,El-Tahir,嗯,据SA; Almaghrabi, M; K B Aljohani; El-Agrody,点;Abulkhair,商品;[2023]
有机化学130 106255
罗伊,CB, Goonetilleke SN;约瑟,L,克里希,一个;萨哈,T,克里安,一个;马瑟,德;[2022]
植物(瑞士巴塞尔)11 (24)
Hurst-Hess KR,菲尔普斯,GA;枯萎,洛杉矶,李,再保险;Ghosh、P;[2022]
肺结核(苏格兰爱丁堡)138 102295
科特,F, Wessendorf CD;施纳贝尔T;·赫尔曼,M; Schroppel, B; Stadelmann, K; Arefaine, E; Busch L;多姆,R; Ahlswede, E,哈特曼,H;[2022]
RSC进步12 (53)34381 - 34392
System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality control internal standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","hs_published_at":1689749511179,"software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
CCD Spectrometer
","link_ja":"https://www.bmglabtech.com/ja/spectrostar-nano/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"6 to 1536-well plates, user-definable
LVis Plate with 16 low-volume microspots (2 μL)
UV/vis absorbance spectrometer
Full spectra or 8 distinct wavelengths in < 1 sec/well
220 - 1000 nm; wavelength precision: ≤ 0.5 nm
","detection_modes":[{"id":60988327692,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/spectrostar-nano/","link_pt":"https://www.bmglabtech.com/pt/spectrostar-nano/","accessories":[{"id":61000765306,"type":"foreignid"},{"id":61000765307,"type":"foreignid"},{"id":61000765309,"type":"foreignid"}],"link_de":"https://www.bmglabtech.com/de/spectrostar-nano/","measurement_modes":"Endpoint and kinetic
Spectral scanning (absorbance)
Well scanning
Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+3 °C above ambient up to 45 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"SPECTROstar Nano ","read_times":"Full spectrum from 220 to 1000 nm in less than 1 sec/well
","sensitivity":"Selectable spectral resolution: 1, 2, 5, and 10 nm
OD range: 0 to 4 OD; photometric resolution: 0.001 OD
Accuracy: < 1% at 2 OD
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD
Linearity: ≤ 0.8% at 2.0 OD
Width: 36 cm, depth: 50 cm, height: 16 cm; weight: 10 kg
"},{"optical_path_guides":"Top: liquid-filled light guides
Bottom: fiber optics
Luminescence (flash and glow) - incl. BRET
","purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","hs_published_at":1689749511179,"software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Low noise photomultiplier tube
","upgrades":"Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","stacker":"Magazines for up to 50 plates - continuous loading feature
","link_ja":"https://www.bmglabtech.com/ja/lumistar-omega/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":1,"microplate_formats":"6 to 384-well plates, user-definable
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/lumistar-omega-teaser.webp","width":418,"height":315,"altText":"","type":"image"},"link_es":"https://www.bmglabtech.com/es/lumistar-omega/","link_cn":"https://www.bmglabtech.com/zh/lumistar-omega/","optical_filters":"Emission filter wheel for 8 filters
","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
Microplates: white for LUM
96 = 96-well microplates
384 = 384-well microplates
Optical filters
","image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/LUMIstar-Omega.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080659291,"spectral_range":"Filters
240 - 740 nm for LUM
Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Top and bottom reading
Endpoint and kinetic
Sequential multi emission
Simultaneous Dual Emission
Ratiometric measurements
Emission filters
","shaking":"Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"LUMIstar Omega","read_times":"16 s (96), 47 s (384)
","sensitivity":"LUM
< 20 amol/well ATP
Width: 44 cm, depth: 48 cm, height: 30 cm; weight: 28 kg
"},{"detection_modes_compare":"UV/vis absorbance spectra
","purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality control internal standards (optional): four NIST-traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","hs_published_at":1689749511179,"software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
CCD Spectrometer
","upgrades":"Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","stacker":"Magazines for up to 50 plates - continuous loading feature
","link_ja":"https://www.bmglabtech.com/ja/spectrostar-omega/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":1,"microplate_formats":"6 to 1536-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
UV/Vis Absorbance Spectrometer
Full spectra or 8 distinct wavelengths in < 1 sec/well
Spectrometer
220 - 1000 nm; wavelength precision: ≤ 0.5 nm
Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Endpoint and kinetic
Spectral scanning (absorbance)
Well scanning
Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"SPECTROstar Omega","read_times":"Full spectrum from 220 to 1000 nm in less than 1 sec/well
","sensitivity":"Selectable spectral resolution: 1, 2, 5, and 10 nm
OD range: 0 to 4 OD; photometric resolution: 0.001 OD
Accuracy: < 1% at 2 OD
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD
Linearity: ≤ 0.8% at 2.0 OD
Width: 44 cm, depth: 48 cm, height: 30 cm; weight: 28 kg
"},{"detection_modes_compare":"Nephelometry (light scattering)
","purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"Self-monitoring laser diode
Wavelength 635±10 nm
Stability <0.2% deviation
Lifetime 20,000 hours
Output: 1 mW
Selectable beam width: 1.5 to 3.5 mm
Selectable intensity 0-100%
Scattering angle: detects up to 80° full cone angle
Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Side window photodiode detector
","upgrades":"Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","stacker":"Magazines for up to 50 plates - continuous loading feature
","link_ja":"https://www.bmglabtech.com/ja/nephelostar-plus/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"Up to 384-well plates
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/nephelostar-plus-teaser.webp","width":419,"height":315,"altText":"","type":"image"},"link_es":"https://www.bmglabtech.com/es/nephelostar-plus/","link_cn":"https://www.bmglabtech.com/zh/nephelostar-plus/","hs_id":59425948219,"hs_child_table_id":0,"wavelength_selection":"Photodiode
Wavelength 635±10 nm
Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Endpoint and kinetic
","priority":5,"shaking":"Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 60 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"NEPHELOstar Plus","read_times":"Depend on assay conditions and liquid surface stability
Shortest times possible: 16 s (96), 47 s (384)
Depending on particle size and liquid properties
Silica detection (particle size 0.5 to 10 µm) 800 nM
Dynamic Range: 5 decades
Maximum count rate (2,000,000 Relative Nephelometry Units (RNUs) per second)
Width: 44 cm, depth: 48 cm, height: 32 cm; weight: 25 kg
"},{"light_sources":"High energy xenon flash lamp
Dedicated laser for AlphaScreen®/AlphaLISA®/AlphaPlex™
Dedicated laser for TRF and TR-FRET
Sample Capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Two matched pairs of photomultiplier tubes (PMTs), optimized for different detection modes
CCD spectrometer
Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","link_ja":"https://www.bmglabtech.com/ja/pherastar-fsx/","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"Up to 3456-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL, optionally up to 2 mL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Linear, orbital, and double-orbital with user-definable time and speed
","zadjustment":"Automatic focal height adjustment (0.1 mm resolution)
","name":"PHERAstar FSX","sensitivity":"FI
(top)
< 0.15 pM FITC (384sv black, 20 μL)
< 0.5 pM FITC (1536 black, 8 μL)
FI
(bottom)
<1.0 pM FITC (384g black, 50 μL)
FP
< 0.5 mP SD at 1 nM FITC (384sv black, 20 μL)
< 1.5 mP SD at 1 nM FITC (1536 black, 8 μL)
TRF with laser.
< 5 fM europium (384, 80 μL)
< 15 fM europium (1536, 8 μL)
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL)
Delta F > 1100% (High Calibrator)
Delta F > 25% (Low Calibrator)
LUM
< 0.4 pM (< 8 amol/well ATP, 384sv white, 20 μL)
Dynamic Range: 9 decades
AlphaScreen® with laser
< 5 pM (< 100 amol/well P-Tyr-100, 384sv white, 20 μL)
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm
OD range: 0 to 4 OD; photometric resolution: 0.001 OD
Accuracy: < 1% at 2 OD
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD
Linearity: ≤ 0.8% at 2.0 OD
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
","detection_modes_compare":"Fluorescence intensity - incl. FRET
Fluorescence polarization
AlphaScreen®/AlphaLISA®/AlphaPlex™
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/Vis absorbance spectra
Magazines for up to 50 plates - continuous loading feature
","microplate_carrier":"Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/pherastar-fsx-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/pherastar-fsx/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
AlphaScreen® P-Tyr-100 assay kit, PerkinElmer, #6760620C
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
1536 = 1536-well microplates
Optic Modules: Up to six application-specific modules (includes all filters, dichroics, etc. for an application)
For top and bottom reading
UV/vis absorbance spectrometer: Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
230 - 750 nm or 230 - 900 nm for FI, FP
230 - 750 nm for LUM
230 - 900 nm for TRF
Spectrometer
220 - 1000 nm for ABS; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Simultaneous Dual Emission
Spectral scanning (absorbance)
Real-time ratiometric measurements
Well scanning
Up to three integrated barcode readers
","do_not_compare":0,"incubation":"+5 °C above ambient up to 45 °C
\nThe upper heating plate of the incubation chamber operates at +0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
\nWith Advanced Assay Stability (AAS) system: from 18 - 45°C
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
14 s (384)
27 s (1536)
10 flashes
38 s (384)
1 min 52 s (1536)
50 flashes
1 min 29 s (384)
5 min 18 s (1536)
Width: 45 cm, depth: 51 cm, height: 47 cm; weight: 49 kg
\nWith AAS system: width: 48 cm, depth: 68 cm, height: 47 cm; weight: 62 kg
"},{"light_sources":"High energy xenon flash lamp
Dedicated laser for AlphaScreen®/AlphaLISA®/AlphaPlex™
Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Integrated fluorophore library
","detectors":"Low-noise photomultiplier tube
Red-shifted photomultiplier tube
CCD spectrometer
The CLARIOstar Plus can include all or any combination of features listed below at purchase. Upgrading with additional features is possible at any time
\nPlease contact your local representative for more details or a quote
","link_ja":"https://www.bmglabtech.com/ja/clariostar-plus/","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"6- to 1536-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Excitation and emission slides for 4 filters each
","hs_id":59433990424,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/CLARIOstar-Plus.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1689749508856,"detection_modes":[{"id":60988327692,"type":"foreignid"},{"id":60988327693,"type":"foreignid"},{"id":61000765297,"type":"foreignid"},{"id":61000765298,"type":"foreignid"},{"id":61000765299,"type":"foreignid"},{"id":61000765300,"type":"foreignid"},{"id":61000765302,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/clariostar-plus/","atmospheric_control_unit_acu":"Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Individual injection volumes for each well: 3 to 500 µL (optionally up to 2 mL)
Variable injection speed up to 420 µL/s
Reagent back flushing
Linear, orbital, and double-orbital with user-definable time and speed
","zadjustment":"Automatic focal height adjustment (0.1 mm resolution)
","name":"CLARIOstar Plus","sensitivity":"FI filters
(top)
< 0.15 pM (< 3 amol/well FITC, 384sv, 20 μL).
FI filters
(bottom)
< 1.0 pM (< 50 amol/well FITC, 384g, 50 μL).
FI monochromator
(top)
< 0.35 pM (< 7 amol/well FITC, 384sv, 20 μL).
FI monochromator
(bottom)
< 3.0 pM (< 150 amol/well FITC, 384g, 50 μL).
Dynamic Range: 8 decades in a single measurement.
FP
< 0.5 mP SD at 1 nM FITC (384sv, 20 μL).
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL).
Delta F > 880% (High Calibrator).
Delta F > 30% (Low Calibrator).
TRF
< 20 fM europium, 384, 80 μL.
LUM
< 0.4 pM (< 8 amol/well ATP, 384sv, 20 μL).
Dynamic range: 8 decades in a single measurement.
AlphaScreen® with laser.
< 5 pM (< 100 amol/well P-Tyr-100, 384sv, 20 μL).
ABS with spectrometer.
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
","detection_modes_compare":"Fluorescence intensity (incl. FRET)
Fluorescence polarization
AlphaScreen®/AlphaLISA®/AlphaPlex™
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/vis absorbance spectra
Magazines for up to 50 plates - continuous loading feature
","microplate_carrier":"Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/clariostar-plus-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/clariostar-plus/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
AlphaScreen® P-Tyr-100 assay kit, PerkinElmer, #6760620C
Microplates: white for LUM, AlphaScreen®, TRF; black for FI, FP; clear for ABS
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
1536 = 1536-well microplates
Dual Linear Variable Filter (LVF) Monochromators™
Linear Variable Dichroic Mirror
Separates ex & em LVF Monochromators
Optical filters:
Ex and em slides hold 4 filters each
LVF Monochromators + optical filters
Use one for ex and the other for em
UV/Vis absorbance spectrometer:
Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
FI, FP, TRF: 240 - 740 nm or 240 - 900 nm (red-shifted PMT)
LUM: 240 - 740 nm
LVF Monochromators™
FI: 320 - 740 nm or 320 - 840 nm (red-shifted PMT)
LUM: 320 - 740 nm
Linear Variable Dichroic
340 - 740 nm or 340 - 760 nm (red-shifted PMT)
Spectrometer
ABS: 220 - 1000 nm; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Spectral scanning (fluorescence, luminescence, absorbance)
Ratiometric measurements
Well scanning
Excitation and emission filters
","integrated_barcode_reader":"Up to two integrated barcode readers
","do_not_compare":0,"incubation":"+3 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
8 s (96), 15 s (384), 28 s (1536)
10 flashes
19 s (96), 57 s (384), 3 min 4 s (1536)
Width: 45 cm, depth: 51 cm, height: 40 cm; weight: 32 kg
"},{"hs_id":61000765304,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/FLUOstar-Omega.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080685756,"hs_published_at":1689749511179,"link_ru":"https://www.bmglabtech.com/ru/omega-series/","link_pt":"https://www.bmglabtech.com/pt/omega-series/","link_ko":"https://www.bmglabtech.com/ko/omega-series/","link":"https://www.bmglabtech.com/en/omega-series/","link_de":"https://www.bmglabtech.com/de/omega-series/","description":"Upgradeable single and multi-mode microplate reader series","priority":10,"do_not_compare":1,"link_ja":"https://www.bmglabtech.com/ja/omega-series/","hs_created_at":1636554660339,"hs_is_edited":false,"name":"Omega Series","hide_in_filters":0,"category":[{"id":60988327690,"type":"foreignid"},{"id":61000765294,"type":"foreignid"},{"id":61000765296,"type":"foreignid"},{"id":64223105625,"type":"foreignid"}],"image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/fluostar-omega-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_es":"https://www.bmglabtech.com/es/omega-series/","link_cn":"https://www.bmglabtech.com/zh/omega-series/","link_fr":"https://www.bmglabtech.com/fr/omega-series/"},{"purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality control internal standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Low noise photomultiplier tube
CCD spectrometer
Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","link_ja":"https://www.bmglabtech.com/ja/fluostar-omega/","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":1,"microplate_formats":"6 to 384-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Excitation and emission filter wheels for 8 filters each
","hs_id":61421181512,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/FLUOstar-Omega.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080689997,"detection_modes":[{"id":60988327692,"type":"foreignid"},{"id":61000765297,"type":"foreignid"},{"id":61000765298,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/fluostar-omega/","atmospheric_control_unit_acu":"Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Linear, orbital, and double-orbital with user-definable time and speed
","name":"FLUOstar Omega","sensitivity":"FI
<0.2 fmol/well FITC.
TRF
< 30 amol/well europium.
LUM
< 20 amol/well ATP.
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
ABS with filters
OD range: 0 to 4 OD
Reproducibility: ±0.010 OD for 0-2 OD range
Top: liquid-filled light guides
Bottom: fiber optics
Fluorescence intensity - incl. FRET
Luminescence (flash and glow) - incl. BRET
UV/Vis absorbance spectra
Magazines for up to 50 plates - continuous loading feature
","microplate_carrier":"Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/fluostar-omega-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/fluostar-omega/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
Microplates: white for LUM; black for FI; clear for ABS
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
Optical filters: ex and em wheels for 8 filters each
UV/vis absorbance spectrometer: full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
240 - 740 nm or 240 - 900 nm for FI
240 - 740 nm for LUM
Spectrometer
220 - 1000 nm for ABS; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi excitation
Sequential multi emission
Simultaneous Dual Emission (FI and LUM)
\nSpectral scanning (absorbance)
Ratiometric measurements
Excitation and emission filters
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
9 s (96), 16 s (384)
Width: 44 cm, depth: 48 cm, height: 30 cm; weight: 28 kg
"},{"light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Smart Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Integrated fluorophore library
","detectors":"Low-noise photomultiplier tube
CCD spectrometer
Upgrades to include options such as additional detection modes, reagent injectors, extended temperature control, etc. are available
\nPlease contact your local representative for more information
","link_ja":"https://www.bmglabtech.com/ja/vantastar/","thermostar":"Microplate incubator and shaker
","hs_created_at":1641149005686,"hide_in_filters":0,"microplate_formats":"6- to 384-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Excitation and emission slides for up to 4 filters each for monochoromator units (VANTAstar), and for up to 5 filters each for filter-only units (VANTAstar F)
","hs_id":63010983478,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/VANTAstar.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080695596,"detection_modes":[{"id":60988327692,"type":"foreignid"},{"id":60988327693,"type":"foreignid"},{"id":61000765297,"type":"foreignid"},{"id":61000765298,"type":"foreignid"},{"id":61000765299,"type":"foreignid"},{"id":61000765302,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/vantastar/","atmospheric_control_unit_acu":"Actively regulates O2 and CO2 - 1-20%
","reagent_injection":"Up to 2 reagent injectors
Individual injection volumes for each well: 3 to 500 μL (optionally up to 1 mL)
Variable injection speed up to 420 μL/s
Reagent back flushing
Heater and stirrer plate
Dimensions: width: 13 cm, depth: 31 cm, height: 26 cm; weight: 6 kg
Linear, circular and double-circular with user-definable time and speed
","zadjustment":"Automatic focal height adjustment (0.1 mm resolution)
","name":"VANTAstar","sensitivity":"FI filters
(top)
< 0.5 pM (< 10 amol/well FITC, 384sv, 20 μL).
FI filters
(bottom)
< 2.5 pM (< 125 amol/well FITC, 384g, 50 μL).
FI monochromator
(top)
< 0.8 pM (< 16 amol/well FITC, 384sv, 20 μL).
FI monochromator
(bottom)
< 3.5 pM (< 175 amol/well FITC, 384g, 50 μL).
Dynamic Range: 8 decades in a single measurement.
FP
< 1.2 mP SD at 1 nM FITC (384sv, 20 μL).
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL).
Delta F > 700% (High Calibrator).
Delta F > 25% (Low Calibrator).
TRF
< 30 fM europium (< 2.4 amol/well, 384, 80 μL).
LUM
< 0.8 pM (< 15 amol/well ATP, 384sv, 20 μL).
Dynamic range: 8 decades in a single measurement.
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
","detection_modes_compare":"Fluorescence intensity (incl. FRET)
Fluorescence polarization
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/vis absorbance spectra
Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/vantastar-teaser.webp","width":419,"height":315,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/vantastar/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
Dual Linear Variable Filter (LVF) Monochromators™
Linear Variable Dichroic Mirror
Separates ex & em LVF Monochromators
Optical filters:
Ex and em slides hold up to 5 filters each
LVF Monochromators + optical filters
Use one for ex and the other for em
UV/Vis absorbance spectrometer: Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
FI, LUM, TRF, FP, TR-FRET: 240 - 740 nm
LVF Monochromators™
FI, LUM: 320 - 740 nm
Linear Variable Dichroic
340 - 740 nm
Spectrometer
ABS: 220 - 1000 nm; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Spectral scanning (fluorescence, luminescence, absorbance)
Ratiometric measurements
Well scanning
Excitation and emission filters
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 60 °C
\nMinimum condensation concept: the upper heating plate of the incubation chamber operates at +0.5 °C than the lower plate, heated optic system
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
9 sec (96), 16 sec (384)
Width: 35 cm, depth: 52 cm, height: 36 cm; weight: 27 kg
"}]" data-initial-product="59433990423">System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality control internal standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","hs_published_at":1689749511179,"software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
CCD Spectrometer
","link_ja":"https://www.bmglabtech.com/ja/spectrostar-nano/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"6 to 1536-well plates, user-definable
LVis Plate with 16 low-volume microspots (2 μL)
UV/vis absorbance spectrometer
Full spectra or 8 distinct wavelengths in < 1 sec/well
220 - 1000 nm; wavelength precision: ≤ 0.5 nm
","detection_modes":[{"id":60988327692,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/spectrostar-nano/","link_pt":"https://www.bmglabtech.com/pt/spectrostar-nano/","accessories":[{"id":61000765306,"type":"foreignid"},{"id":61000765307,"type":"foreignid"},{"id":61000765309,"type":"foreignid"}],"link_de":"https://www.bmglabtech.com/de/spectrostar-nano/","measurement_modes":"Endpoint and kinetic
Spectral scanning (absorbance)
Well scanning
Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+3 °C above ambient up to 45 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"SPECTROstar Nano ","read_times":"Full spectrum from 220 to 1000 nm in less than 1 sec/well
","sensitivity":"Selectable spectral resolution: 1, 2, 5, and 10 nm
OD range: 0 to 4 OD; photometric resolution: 0.001 OD
Accuracy: < 1% at 2 OD
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD
Linearity: ≤ 0.8% at 2.0 OD
Width: 36 cm, depth: 50 cm, height: 16 cm; weight: 10 kg
"},{"optical_path_guides":"Top: liquid-filled light guides
Bottom: fiber optics
Luminescence (flash and glow) - incl. BRET
","purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","hs_published_at":1689749511179,"software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Low noise photomultiplier tube
","upgrades":"Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","stacker":"Magazines for up to 50 plates - continuous loading feature
","link_ja":"https://www.bmglabtech.com/ja/lumistar-omega/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":1,"microplate_formats":"6 to 384-well plates, user-definable
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/lumistar-omega-teaser.webp","width":418,"height":315,"altText":"","type":"image"},"link_es":"https://www.bmglabtech.com/es/lumistar-omega/","link_cn":"https://www.bmglabtech.com/zh/lumistar-omega/","optical_filters":"Emission filter wheel for 8 filters
","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
Microplates: white for LUM
96 = 96-well microplates
384 = 384-well microplates
Optical filters
","image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/LUMIstar-Omega.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080659291,"spectral_range":"Filters
240 - 740 nm for LUM
Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Top and bottom reading
Endpoint and kinetic
Sequential multi emission
Simultaneous Dual Emission
Ratiometric measurements
Emission filters
","shaking":"Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"LUMIstar Omega","read_times":"16 s (96), 47 s (384)
","sensitivity":"LUM
< 20 amol/well ATP
Width: 44 cm, depth: 48 cm, height: 30 cm; weight: 28 kg
"},{"detection_modes_compare":"UV/vis absorbance spectra
","purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality control internal standards (optional): four NIST-traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","hs_published_at":1689749511179,"software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
CCD Spectrometer
","upgrades":"Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","stacker":"Magazines for up to 50 plates - continuous loading feature
","link_ja":"https://www.bmglabtech.com/ja/spectrostar-omega/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":1,"microplate_formats":"6 to 1536-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
UV/Vis Absorbance Spectrometer
Full spectra or 8 distinct wavelengths in < 1 sec/well
Spectrometer
220 - 1000 nm; wavelength precision: ≤ 0.5 nm
Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Endpoint and kinetic
Spectral scanning (absorbance)
Well scanning
Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"SPECTROstar Omega","read_times":"Full spectrum from 220 to 1000 nm in less than 1 sec/well
","sensitivity":"Selectable spectral resolution: 1, 2, 5, and 10 nm
OD range: 0 to 4 OD; photometric resolution: 0.001 OD
Accuracy: < 1% at 2 OD
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD
Linearity: ≤ 0.8% at 2.0 OD
Width: 44 cm, depth: 48 cm, height: 30 cm; weight: 28 kg
"},{"detection_modes_compare":"Nephelometry (light scattering)
","purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"Self-monitoring laser diode
Wavelength 635±10 nm
Stability <0.2% deviation
Lifetime 20,000 hours
Output: 1 mW
Selectable beam width: 1.5 to 3.5 mm
Selectable intensity 0-100%
Scattering angle: detects up to 80° full cone angle
Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Side window photodiode detector
","upgrades":"Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","stacker":"Magazines for up to 50 plates - continuous loading feature
","link_ja":"https://www.bmglabtech.com/ja/nephelostar-plus/","microplate_carrier":"Robot compatible
","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"Up to 384-well plates
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/nephelostar-plus-teaser.webp","width":419,"height":315,"altText":"","type":"image"},"link_es":"https://www.bmglabtech.com/es/nephelostar-plus/","link_cn":"https://www.bmglabtech.com/zh/nephelostar-plus/","hs_id":59425948219,"hs_child_table_id":0,"wavelength_selection":"Photodiode
Wavelength 635±10 nm
Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Endpoint and kinetic
","priority":5,"shaking":"Linear, orbital, and double-orbital with user-definable time and speed
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 60 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"name":"NEPHELOstar Plus","read_times":"Depend on assay conditions and liquid surface stability
Shortest times possible: 16 s (96), 47 s (384)
Depending on particle size and liquid properties
Silica detection (particle size 0.5 to 10 µm) 800 nM
Dynamic Range: 5 decades
Maximum count rate (2,000,000 Relative Nephelometry Units (RNUs) per second)
Width: 44 cm, depth: 48 cm, height: 32 cm; weight: 25 kg
"},{"light_sources":"High energy xenon flash lamp
Dedicated laser for AlphaScreen®/AlphaLISA®/AlphaPlex™
Dedicated laser for TRF and TR-FRET
Sample Capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Two matched pairs of photomultiplier tubes (PMTs), optimized for different detection modes
CCD spectrometer
Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","link_ja":"https://www.bmglabtech.com/ja/pherastar-fsx/","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"Up to 3456-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL, optionally up to 2 mL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Linear, orbital, and double-orbital with user-definable time and speed
","zadjustment":"Automatic focal height adjustment (0.1 mm resolution)
","name":"PHERAstar FSX","sensitivity":"FI
(top)
< 0.15 pM FITC (384sv black, 20 μL)
< 0.5 pM FITC (1536 black, 8 μL)
FI
(bottom)
<1.0 pM FITC (384g black, 50 μL)
FP
< 0.5 mP SD at 1 nM FITC (384sv black, 20 μL)
< 1.5 mP SD at 1 nM FITC (1536 black, 8 μL)
TRF with laser.
< 5 fM europium (384, 80 μL)
< 15 fM europium (1536, 8 μL)
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL)
Delta F > 1100% (High Calibrator)
Delta F > 25% (Low Calibrator)
LUM
< 0.4 pM (< 8 amol/well ATP, 384sv white, 20 μL)
Dynamic Range: 9 decades
AlphaScreen® with laser
< 5 pM (< 100 amol/well P-Tyr-100, 384sv white, 20 μL)
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm
OD range: 0 to 4 OD; photometric resolution: 0.001 OD
Accuracy: < 1% at 2 OD
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD
Linearity: ≤ 0.8% at 2.0 OD
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
","detection_modes_compare":"Fluorescence intensity - incl. FRET
Fluorescence polarization
AlphaScreen®/AlphaLISA®/AlphaPlex™
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/Vis absorbance spectra
Magazines for up to 50 plates - continuous loading feature
","microplate_carrier":"Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/pherastar-fsx-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/pherastar-fsx/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
AlphaScreen® P-Tyr-100 assay kit, PerkinElmer, #6760620C
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
1536 = 1536-well microplates
Optic Modules: Up to six application-specific modules (includes all filters, dichroics, etc. for an application)
For top and bottom reading
UV/vis absorbance spectrometer: Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
230 - 750 nm or 230 - 900 nm for FI, FP
230 - 750 nm for LUM
230 - 900 nm for TRF
Spectrometer
220 - 1000 nm for ABS; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Simultaneous Dual Emission
Spectral scanning (absorbance)
Real-time ratiometric measurements
Well scanning
Up to three integrated barcode readers
","do_not_compare":0,"incubation":"+5 °C above ambient up to 45 °C
\nThe upper heating plate of the incubation chamber operates at +0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
\nWith Advanced Assay Stability (AAS) system: from 18 - 45°C
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
14 s (384)
27 s (1536)
10 flashes
38 s (384)
1 min 52 s (1536)
50 flashes
1 min 29 s (384)
5 min 18 s (1536)
Width: 45 cm, depth: 51 cm, height: 47 cm; weight: 49 kg
\nWith AAS system: width: 48 cm, depth: 68 cm, height: 47 cm; weight: 62 kg
"},{"light_sources":"High energy xenon flash lamp
Dedicated laser for AlphaScreen®/AlphaLISA®/AlphaPlex™
Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Integrated fluorophore library
","detectors":"Low-noise photomultiplier tube
Red-shifted photomultiplier tube
CCD spectrometer
The CLARIOstar Plus can include all or any combination of features listed below at purchase. Upgrading with additional features is possible at any time
\nPlease contact your local representative for more details or a quote
","link_ja":"https://www.bmglabtech.com/ja/clariostar-plus/","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":0,"microplate_formats":"6- to 1536-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Excitation and emission slides for 4 filters each
","hs_id":59433990424,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/CLARIOstar-Plus.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1689749508856,"detection_modes":[{"id":60988327692,"type":"foreignid"},{"id":60988327693,"type":"foreignid"},{"id":61000765297,"type":"foreignid"},{"id":61000765298,"type":"foreignid"},{"id":61000765299,"type":"foreignid"},{"id":61000765300,"type":"foreignid"},{"id":61000765302,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/clariostar-plus/","atmospheric_control_unit_acu":"Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Individual injection volumes for each well: 3 to 500 µL (optionally up to 2 mL)
Variable injection speed up to 420 µL/s
Reagent back flushing
Linear, orbital, and double-orbital with user-definable time and speed
","zadjustment":"Automatic focal height adjustment (0.1 mm resolution)
","name":"CLARIOstar Plus","sensitivity":"FI filters
(top)
< 0.15 pM (< 3 amol/well FITC, 384sv, 20 μL).
FI filters
(bottom)
< 1.0 pM (< 50 amol/well FITC, 384g, 50 μL).
FI monochromator
(top)
< 0.35 pM (< 7 amol/well FITC, 384sv, 20 μL).
FI monochromator
(bottom)
< 3.0 pM (< 150 amol/well FITC, 384g, 50 μL).
Dynamic Range: 8 decades in a single measurement.
FP
< 0.5 mP SD at 1 nM FITC (384sv, 20 μL).
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL).
Delta F > 880% (High Calibrator).
Delta F > 30% (Low Calibrator).
TRF
< 20 fM europium, 384, 80 μL.
LUM
< 0.4 pM (< 8 amol/well ATP, 384sv, 20 μL).
Dynamic range: 8 decades in a single measurement.
AlphaScreen® with laser.
< 5 pM (< 100 amol/well P-Tyr-100, 384sv, 20 μL).
ABS with spectrometer.
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
","detection_modes_compare":"Fluorescence intensity (incl. FRET)
Fluorescence polarization
AlphaScreen®/AlphaLISA®/AlphaPlex™
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/vis absorbance spectra
Magazines for up to 50 plates - continuous loading feature
","microplate_carrier":"Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/clariostar-plus-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/clariostar-plus/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
AlphaScreen® P-Tyr-100 assay kit, PerkinElmer, #6760620C
Microplates: white for LUM, AlphaScreen®, TRF; black for FI, FP; clear for ABS
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
1536 = 1536-well microplates
Dual Linear Variable Filter (LVF) Monochromators™
Linear Variable Dichroic Mirror
Separates ex & em LVF Monochromators
Optical filters:
Ex and em slides hold 4 filters each
LVF Monochromators + optical filters
Use one for ex and the other for em
UV/Vis absorbance spectrometer:
Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
FI, FP, TRF: 240 - 740 nm or 240 - 900 nm (red-shifted PMT)
LUM: 240 - 740 nm
LVF Monochromators™
FI: 320 - 740 nm or 320 - 840 nm (red-shifted PMT)
LUM: 320 - 740 nm
Linear Variable Dichroic
340 - 740 nm or 340 - 760 nm (red-shifted PMT)
Spectrometer
ABS: 220 - 1000 nm; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Spectral scanning (fluorescence, luminescence, absorbance)
Ratiometric measurements
Well scanning
Excitation and emission filters
","integrated_barcode_reader":"Up to two integrated barcode readers
","do_not_compare":0,"incubation":"+3 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
8 s (96), 15 s (384), 28 s (1536)
10 flashes
19 s (96), 57 s (384), 3 min 4 s (1536)
Width: 45 cm, depth: 51 cm, height: 40 cm; weight: 32 kg
"},{"hs_id":61000765304,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/FLUOstar-Omega.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080685756,"hs_published_at":1689749511179,"link_ru":"https://www.bmglabtech.com/ru/omega-series/","link_pt":"https://www.bmglabtech.com/pt/omega-series/","link_ko":"https://www.bmglabtech.com/ko/omega-series/","link":"https://www.bmglabtech.com/en/omega-series/","link_de":"https://www.bmglabtech.com/de/omega-series/","description":"Upgradeable single and multi-mode microplate reader series","priority":10,"do_not_compare":1,"link_ja":"https://www.bmglabtech.com/ja/omega-series/","hs_created_at":1636554660339,"hs_is_edited":false,"name":"Omega Series","hide_in_filters":0,"category":[{"id":60988327690,"type":"foreignid"},{"id":61000765294,"type":"foreignid"},{"id":61000765296,"type":"foreignid"},{"id":64223105625,"type":"foreignid"}],"image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/fluostar-omega-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_es":"https://www.bmglabtech.com/es/omega-series/","link_cn":"https://www.bmglabtech.com/zh/omega-series/","link_fr":"https://www.bmglabtech.com/fr/omega-series/"},{"purge_gas_vent":"System to inject an atmosphere or to pull a vacuum into the reader
","light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality control internal standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Reader Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Low noise photomultiplier tube
CCD spectrometer
Please contact your local representative for upgrades including options such as detection modes, reagent injectors, etc
","link_ja":"https://www.bmglabtech.com/ja/fluostar-omega/","thermostar":"Microplate incubator and shaker
","hs_created_at":1636554660339,"hide_in_filters":1,"microplate_formats":"6 to 384-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Excitation and emission filter wheels for 8 filters each
","hs_id":61421181512,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/FLUOstar-Omega.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080689997,"detection_modes":[{"id":60988327692,"type":"foreignid"},{"id":61000765297,"type":"foreignid"},{"id":61000765298,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/fluostar-omega/","atmospheric_control_unit_acu":"Actively regulates O2 and CO2 - 0.1-20%
","reagent_injection":"Up to 2 built-in reagent injectors
Injection at measurement position (6 to 384-well)
Individual injection volumes for each well (3 to 500 µL)
Variable injection speed up to 420 µL/s
Up to four injection events per well
Reagent back flushing
Linear, orbital, and double-orbital with user-definable time and speed
","name":"FLUOstar Omega","sensitivity":"FI
<0.2 fmol/well FITC.
TRF
< 30 amol/well europium.
LUM
< 20 amol/well ATP.
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
ABS with filters
OD range: 0 to 4 OD
Reproducibility: ±0.010 OD for 0-2 OD range
Top: liquid-filled light guides
Bottom: fiber optics
Fluorescence intensity - incl. FRET
Luminescence (flash and glow) - incl. BRET
UV/Vis absorbance spectra
Magazines for up to 50 plates - continuous loading feature
","microplate_carrier":"Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/fluostar-omega-teaser.webp","width":418,"height":314,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/fluostar-omega/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
Microplates: white for LUM; black for FI; clear for ABS
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
Optical filters: ex and em wheels for 8 filters each
UV/vis absorbance spectrometer: full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
240 - 740 nm or 240 - 900 nm for FI
240 - 740 nm for LUM
Spectrometer
220 - 1000 nm for ABS; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi excitation
Sequential multi emission
Simultaneous Dual Emission (FI and LUM)
\nSpectral scanning (absorbance)
Ratiometric measurements
Excitation and emission filters
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 65 °C
\nThe upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
9 s (96), 16 s (384)
Width: 44 cm, depth: 48 cm, height: 30 cm; weight: 28 kg
"},{"light_sources":"High energy xenon flash lamp
","lvis_plate":"Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
\nQuality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
\nDimensions: conforms to SBS standards for microplates
","software":"Multi-user Smart Control and MARS Data Analysis Software included
FDA 21 CFR Part 11 compliant
Integrated fluorophore library
","detectors":"Low-noise photomultiplier tube
CCD spectrometer
Upgrades to include options such as additional detection modes, reagent injectors, extended temperature control, etc. are available
\nPlease contact your local representative for more information
","link_ja":"https://www.bmglabtech.com/ja/vantastar/","thermostar":"Microplate incubator and shaker
","hs_created_at":1641149005686,"hide_in_filters":0,"microplate_formats":"6- to 384-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Excitation and emission slides for up to 4 filters each for monochoromator units (VANTAstar), and for up to 5 filters each for filter-only units (VANTAstar F)
","hs_id":63010983478,"hs_child_table_id":0,"image":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/2_Products/1_Current%20Products%20u.%20Accessories/VANTAstar.webp","width":600,"height":600,"altText":"","type":"image"},"hs_updated_at":1675080695596,"detection_modes":[{"id":60988327692,"type":"foreignid"},{"id":60988327693,"type":"foreignid"},{"id":61000765297,"type":"foreignid"},{"id":61000765298,"type":"foreignid"},{"id":61000765299,"type":"foreignid"},{"id":61000765302,"type":"foreignid"}],"link_ru":"https://www.bmglabtech.com/ru/vantastar/","atmospheric_control_unit_acu":"Actively regulates O2 and CO2 - 1-20%
","reagent_injection":"Up to 2 reagent injectors
Individual injection volumes for each well: 3 to 500 μL (optionally up to 1 mL)
Variable injection speed up to 420 μL/s
Reagent back flushing
Heater and stirrer plate
Dimensions: width: 13 cm, depth: 31 cm, height: 26 cm; weight: 6 kg
Linear, circular and double-circular with user-definable time and speed
","zadjustment":"Automatic focal height adjustment (0.1 mm resolution)
","name":"VANTAstar","sensitivity":"FI filters
(top)
< 0.5 pM (< 10 amol/well FITC, 384sv, 20 μL).
FI filters
(bottom)
< 2.5 pM (< 125 amol/well FITC, 384g, 50 μL).
FI monochromator
(top)
< 0.8 pM (< 16 amol/well FITC, 384sv, 20 μL).
FI monochromator
(bottom)
< 3.5 pM (< 175 amol/well FITC, 384g, 50 μL).
Dynamic Range: 8 decades in a single measurement.
FP
< 1.2 mP SD at 1 nM FITC (384sv, 20 μL).
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL).
Delta F > 700% (High Calibrator).
Delta F > 25% (Low Calibrator).
TRF
< 30 fM europium (< 2.4 amol/well, 384, 80 μL).
LUM
< 0.8 pM (< 15 amol/well ATP, 384sv, 20 μL).
Dynamic range: 8 decades in a single measurement.
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
","detection_modes_compare":"Fluorescence intensity (incl. FRET)
Fluorescence polarization
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/vis absorbance spectra
Robot compatible
","image_additional":{"url":"https://www.bmglabtech.com/hubfs/1_Webseite/8_Special%20Images/Teaser/Products%20Accessories/vantastar-teaser.webp","width":419,"height":315,"altText":"","type":"image"},"link_cn":"https://www.bmglabtech.com/zh/vantastar/","misc":"LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
Dual Linear Variable Filter (LVF) Monochromators™
Linear Variable Dichroic Mirror
Separates ex & em LVF Monochromators
Optical filters:
Ex and em slides hold up to 5 filters each
LVF Monochromators + optical filters
Use one for ex and the other for em
UV/Vis absorbance spectrometer: Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
FI, LUM, TRF, FP, TR-FRET: 240 - 740 nm
LVF Monochromators™
FI, LUM: 320 - 740 nm
Linear Variable Dichroic
340 - 740 nm
Spectrometer
ABS: 220 - 1000 nm; wavelength precision: ≤ 0.5 nm
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Spectral scanning (fluorescence, luminescence, absorbance)
Ratiometric measurements
Well scanning
Excitation and emission filters
","do_not_compare":0,"incubation":"+4 °C above ambient up to 45 °C or 60 °C
\nMinimum condensation concept: the upper heating plate of the incubation chamber operates at +0.5 °C than the lower plate, heated optic system
","hs_is_edited":false,"read_times":"Flying mode (1 flash)
9 sec (96), 16 sec (384)
Width: 35 cm, depth: 52 cm, height: 36 cm; weight: 27 kg
"}]" data-initial-product="59433990423">